RPS-2100 Controller With Remote
Sensing Head
- Various
Sensing Ranges
- Low
Frequency - 38.5 kHz
- 2-Way
Power Operation
- Small
Remote Transducer
- 2
Independent Range Adjustments
-
LED Indicators
- Isolated
Form C Relay Outputs
- Small
Electronic Controller
|
 |
The RPS-2100 is
a single transducer device with 2 independent
range control adjustments, LED indicators, and
form C relay outputs. These make the sensor well
suited for high and low level control, or other
applications where two set points are needed. This
sensor also has a unique master and slave feature
which enables many of the same units to be used
within close proximity of one another without
cross-talk interference. For example, if three
sensors are needed in a close area, one sensor
would be left as a master and the other two would
be slaves. This is done by means of the X IN, X
OUT, and GND connection on the board. One sensor
(master) would send a signal by means of the X OUT
and GND terminals. These would be connected to the
X IN and GND terminals of the other two sensors
(slaves). With the sensors connected in this way,
all units would be transmitting and receiving at
the same time. This then would prevent cross-talk
and enable all three sensors to be used at the
same time in close proximity of one another.
There are also
separate turn ON and turn OFF DELAY potentiometers
provided for each set point. All four DELAY
controls are located along side the black module
inside the enclosure box. The remote transducer
allows for mounting of the sensor head in cramped
spaces while the controller is out of the way. The
(2) independent and isolated form C relays furnish
N.O. and N.C. outputs. This sensor operates at a
frequency of 38.5kHz, has a broad sensing beam
which allows for detection of an object at greater
angles of tilt. Sensing ranges available for the
RPS-2100 include 2" to 14", 5" to 72", and 10" to
240". Mounting flanges, LED indicators, ranging
potentiometers, and 6-ft. transducer cable are
included. Optional cable lengths are available.

Proximity Detection
Proximity detection is the
detection of an object in a given range. The
detection range of the RPS-2100 is controlled by
the "Range Control" potentiometer located on the
front cover of the controller. Any object within
the desired range is detected, while objects out
of range are ignored. The detect point is
independent of size, material, and reflectivity.
The Proximity Option is denoted byt the part
number RPS-2100-14.
Level Control
The RPS-2100
provides 2 individual set points with independent
relay outputs. The most common application for
this unit is in level control. Using the range
control potentiometers a high set point (SP 1) and
a low set point (SP 2) can be set to keep a level
in between a specific window. When the level goes
above the high point (SP 1), relay one would be
activated. If the level goes below the low point
(SP 2), relay two would be activated. The Level
Control Option is denoted by using the same part
number as the Proximity Option. (Example:
RPS-2100-14)
|
Product
Specifications: |
|
Operational Range:
Power Input: 120VAC:
Input Current:
Ambient Temperature:
Enclosure: Controller:
Transducer:
Output (2) N.O., NC.
Transducer Frequency: |
Adjustable 2" to 14"
Adjustable 5" to 72"
Adjustable10" to 240"
120VAC
15-24 VDC
40 Milliamps
0ºC to 60ºC
or 32ºF to 140ºF
Metal Enclosure
Aluminum Transducer in
Epoxy filled plastic housing
Isolated Form C Relay
.5 Amp Max. at 120 VAC
38.5 kHz |
|
Adjustable Response Time: |
2" to 14" |
5" to 72" |
10" to 240" |
|
|
ON |
|
30mS - 2S |
100mS - 2S |
250mS - 2S |
|
OFF |
|
30mS - 2S |
100mS - 2S |
250mS - 2S |
| |
|
|
|
|
|
Weight of Controller: |
34.2 ounces |
|
Weight of Transducer: |
4.5 ounces |
|
|
|
 |
| Figure: |
|
|
|
A-Angle of Tilt
B-Beam Spread
C-Wiring Diag. - For RPS-2100
D-Wiring Diag. - For Master - Slave
configuration
E- Delay Controls for RPS-2100
F-Mounting Dimensions |
|
 |
PART NUMBER |
RANGE |
OUTPUT |
RPS-2100-14
RPS-2100-72
RPS-2100-240 |
2" -
14"
5" - 72"
10" - 240" |
(2) Isolated Form C Relays
(2) Isolated Form C Relays
(2) Isolated Form C Relays
|
|